Download Avaya Pod Fx Integration Exam.7593X.Pass4Sure.2018-06-27.39q.vcex

Vendor: Avaya
Exam Code: 7593X
Exam Name: Avaya Pod Fx Integration Exam
Date: Jun 27, 2018
File Size: 2 MB

How to open VCEX files?

Files with VCEX extension can be opened by ProfExam Simulator.

Purchase
Coupon: EXAM_HUB

Discount: 20%

Demo Questions

Question 1
For Pod Visualization Manager (PVM) to reflect the addition of a new compute server in the Pod, what would an administrator need to do?
  1. Configure the serviceability agent using VPFM-Inventory.
  2. Configure the serviceability agent using PVM - Administrative functions - Preferences.
  3. Configure the serviceability agent to automatically discover the new compute server.
  4. Configure the serviceability agent using PVM – Administrative functions – Profile.
Correct answer: C
Question 2
Which Pod Orchestration Suite (POS) application allows the administrator to run the off-box EDM management platform for VSP network switches?
  1. Virtualization Provisioning Service
  2. Configuration Orchestration Manager
  3. Pod Visualization Manager
  4. Visualization Performance and Fault Manager
Correct answer: A
Question 3
For the Virtualization Provisioning Service (VPS) application to function correctly, it needs to communicate with the vCenter Server. 
Where are the login credentials for the vCenter Server configured?
  1. in SMGR > Administrators
  2. in Device and Server Credentials Editor
  3. in PVM > Administrative functions > Profile
  4. in VPS > Preferences > vCenter Server
Correct answer: D
Question 4
  
Refer to the exhibit. 
How can an administrator change the Pod Visualization Manager (PVM) threshold values of the CPU, Memory, and Temperature measurements?
  1. by modifying the SNMP threshold values in VPFM-Inventory
  2. by modifying the values in PVM - Administrative functions – Preferences.
  3. by modifying the values in PVM – Administrative functions – Profile.
  4. The default threshold values cannot be changed.
Correct answer: A
Question 5
Typically, when is a new Pod dashboard added to Visualization Performance and Fault Management (VPFM)?
  1. when the Main Pod is upgraded
  2. when the original dashboard is no longer updated information
  3. when the original dashboard runs out of space
  4. when a new Extension Pod is added after initial deployment
Correct answer: D
Question 6
Which two statements are true regarding IP Flow Manager (IPFM)? (Choose two.)
  1. Built-in well know ports are monitored.
  2. IPFM is launched by selecting the IPFM link on COM Navigation Menu.
  3. User defined ports can be added.
  4. Traffic flow can be collected from all Pod components.
Correct answer: CD
Question 7
Assuming a new device resides in a subnet that has not been discovered, which three actions will ensure that Visualization Performance and Fault Management (VPFM) successfully discovers the newly added component to the Pod? (Choose three.)
  1. Seed router or subnet information of the Pod needs to be added to VPFM.
  2. SNMP credentials of the new components need to be added to the Device and Server Credential Editor.
  3. A test Trap should be generated from the newly added component.
  4. Rediscovery needs to be run in VPFM.
  5. The Pod Visualization Manager (PVM) Profile must include the newly added component.
Correct answer: ABC
Question 8
When configuring an Email Action in Visualization Performance and Fault Management (VPFM), which two statements are true? (Choose two.)
  1. An optional file attachment may be included in the email.
  2. The SMTP username and password fields are mandatory.
  3. An optional backup SMTP server may be configured.
  4. The subject field is optional.
Correct answer: BC
Explanation:
Reference: https://downloads.avaya.com/css/P8/documents/100158782
Reference: https://downloads.avaya.com/css/P8/documents/100158782
Question 9
  
Refer to the exhibit. 
When configuring Visualization Performance and Fault Management (VPFM) Actions, why should the option for ‘The repetition count of an event increments’ be used with caution?
  1. It could generate a large amount of emails if associated with an Email action.
  2. It could cause the loss of the timestamp information of the original event.
  3. It could generate a large amount of Syslog entries on the VPFM server.
  4. It could cause a large amount to duplicate entries in the VPFM event browser.
Correct answer: C
Question 10
When a new instance and new VMs are added to Pod Fx, additional configuration is required on Visualization Performance and Fault Management (VPFM). 
Which two actions are required for this configuration? (Choose two.)
  1. Add the new VMs to VPFM’s inventory.
  2. Enable Monitoring for the new domain.
  3. Create a new domain for the new Instance.
  4. Deploy and configure a new VPFM VM.
Correct answer: AC
HOW TO OPEN VCE FILES

Use VCE Exam Simulator to open VCE files
Avanaset

HOW TO OPEN VCEX AND EXAM FILES

Use ProfExam Simulator to open VCEX and EXAM files
ProfExam Screen

ProfExam
ProfExam at a 20% markdown

You have the opportunity to purchase ProfExam at a 20% reduced price

Get Now!