Question 1
A customer needs to monitor device health, obtain warranty status, and track support cases for its HPE ProLiant Gen8 and 9 servers as well as its HPE Smart Storage products. 
Which tool meets the customer’s needs?
  1. HPE Insight Remote Support
  2. Active Health System
  3. HPE Insight Diagnostics Online Edition
  4. HPE Insight Control Server Provisioning
Correct answer: C
Question 2
Which technology provides monitoring of power consumption at the core, load segment, stick, and outlet level with precision and accuracy in a core-and-stick architecture?
  1. HPE iPDU
  2. HPE UPS
  3. HPE Power Advisor
  4. HPE Thermal Discovery Services
Correct answer: A
Explanation:
Using the popular core and stick architecture of HP’s Modular PDU line the HP Intelligent PDU provides monitoring of power consumption at the core, load segment, stick, and outlet level with unmatched precision and accuracy. Remote management is built in and even provides power cycle ability of individual outlet on the Intelligent Extension Bars. HP is also the first to incorporate Intelligent Power Discovery, which when combined with HP’s line of Platinum level high efficiency power supplies the Intelligent PDU actually communicates with the attached servers to collect asset information for the automatic mapping of the power topology inside a rack, greatly reducing the risk of human errors that can cause power outages. Reference: https://ccnytech.com/product/hp-6-outlet-power-distribution-unit-3/
Using the popular core and stick architecture of HP’s Modular PDU line the HP Intelligent PDU provides monitoring of power consumption at the core, load segment, stick, and outlet level with unmatched precision and accuracy. Remote management is built in and even provides power cycle ability of individual outlet on the Intelligent Extension Bars. HP is also the first to incorporate Intelligent Power Discovery, which when combined with HP’s line of Platinum level high efficiency power supplies the Intelligent PDU actually communicates with the attached servers to collect asset information for the automatic mapping of the power topology inside a rack, greatly reducing the risk of human errors that can cause power outages. 
Reference: https://ccnytech.com/product/hp-6-outlet-power-distribution-unit-3/
Question 3
An integrator installs an HPE ProLiant BL 460c Gen9 server into an HPE c7000 BladeSystem Enclosure that has HPE Virtual Connect Flex-10 Ethernet modules in interconnect bays 1 and 2, and HPE Virtual Connect 8Gb 24-Port Fibre Channel modules in interconnect bays 3-6. The blade is configured with two HPE LPe1605 16Gb Fibre Channel HBAs in mezzanine slots 1 and 2, 32 Gb memory, and a single E-2600 v3 processor. 
Next, the integrator installs ESXi 5.5 update 2 on the server. However, only one HBA is recognized in the operating system. As a troubleshooting step, the integrator replaces the HBAs in the problem server with known working HBAs from another server. However, ESXi still recognizes only one HBA. 
Which step should the integrator take to allow the server to recognize both HBAs?
  1. Enable the 2nd HBA in the Onboard Administrator.
  2. Install an additional 32Gb memory to allow the blade to access the 2nd mezzanine slot.
  3. Install a 2nd processor to allow the blade to access the 2nd mezzanine slot.
  4. Create two additional SAN Fabrics in Virtual Connect Manager for the 2nd HBA to use.
Correct answer: C
Question 4
An integrator needs to ensure that an HPE ProLiant ML150 Gen9 Server consistently has the most current updates for firmware and drives. 
Which tool’s current version should the integrator use to accomplish this?
  1. HPE Service Pack for ProLiant
  2. HPE Firmware Management DVD
  3. HPE Insight Online
  4. HPE Onboard Administrator
Correct answer: C
Explanation:
Reference: https://www.hpe.com/h20195/v2/GetPDF.aspx/c04447843.pdf
Reference: https://www.hpe.com/h20195/v2/GetPDF.aspx/c04447843.pdf
Question 5
A customer’s data center has cool air distributed by means of the plenum under the raised floor. 
What should the integrator recommend to the customer to enable more efficient cooling of the rack-mounted HPE ProLiant Gen9 servers?
  1. Close the open gaps in the front of the racks by using blanking panels.
  2. Raise the pressure of the cold air under the raised floor.
  3. Place ventilated tiles in the hot aisle of the data center.
  4. Lower the air inlet temperature of the HPE ProLiant servers to 65° F (18° C).
Correct answer: B
Question 6
An integrator with 25 HPE ProLiant servers that run MS Windows Server 2012 needs to ensure that the latest drives and firmware are installed. 
Which tool should the integrator use to accomplish this?
  1. HPE SUM
  2. MS Windows Server Update Services
  3. HPE Active Health System
  4. HPE Intelligent Provisioning
Correct answer: D
Explanation:
Reference: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-c03478429
Reference: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-c03478429
Question 7
An HPE ProLiant Gen9 server running Server 2012 located at a remote site is not functioning property and cannot be accessed by any Remote Desktop applications. An integrator at the data center needs to access this remote server and find out what is causing the issue. 
Which tool on the remote server can the integrator use to accomplish this?
  1. Integrated Management Log
  2. MS Windows Event Viewer Logs
  3. Embedded UEFI Shell
  4. Active Health System Log
Correct answer: C
Question 8
A customer needs a solution to prevent their five HPE ProLiant DL380 Gen9 servers from powering off due to a 10-second utility power loss. 
Which power support solution should the integrator recommend to the customer?
  1. Change the Redundant Power Supply mode for the HPE ProLiant Gen9 server to Balanced Mode.
  2. Install an HPE Smart Storage battery for each HPE ProLiant Gen9 server
  3. Install an HPE T750 UPS.
  4. Install an HPE R5000 UPS.
Correct answer: C
Question 9
A facility has several Gen9 Blade Systems, one of which failed. The integrator needs to configure an Active/Active configuration for high availability so the failure is avoided in the future. 
How many FlexFabric modules and switches does the integrator need, at a minimum, to achieve this?
  1. 2 FlexFabric modules, 1 Top of Rack switch
  2. 1 FlexFabric module, 1 data center switch
  3. 1 FlexFabric module, 2 Top of Rack switches
  4. 2 FlexFabric modules, 2 data center switches
Correct answer: C
Question 10
What is a benefit of using 20Gb FlexFabric converged network adapter (CAN) for the BladeSystems?
  1. Performance is delivered through multiple 2/10Gb ports using multiple adapters in a teamed fashion.
  2. it allows support for RDMA over Converged Ethernet (RCOE) when the HP 6125XLG is used in conjunction with the FlexFabric adapter
  3. It delivers 10Gb performance per port with an aggregate 20Gb in a dual-port adapter.
  4. The adapter streams converge 10GbE and 16Gb storage simultaneously over the same 20Gb port.
Correct answer: A