Download FlexPod Implementation and Administration.NS0-171.PassGuide.2018-12-09.34q.vcex

Vendor: Network Appliance
Exam Code: NS0-171
Exam Name: FlexPod Implementation and Administration
Date: Dec 09, 2018
File Size: 3 MB

How to open VCEX files?

Files with VCEX extension can be opened by ProfExam Simulator.

Purchase
Coupon: EXAM_HUB

Discount: 20%

Demo Questions

Question 1
Which set of commands maps VLAN 100 to VSAN 100? 
  1. Nexus 5000-A#configure terminal 
    Nexus 5000-A (config) # vlan 100 
    Nexus 5000- A (config-vlan_ #fcoe vsan 100
  2. Nexus 5000-B# configure terminal 
    Nexus 5000-B (config) # vsan database 
    Nexus 5000-B (config-vsan)# vsan 100 
    Nexus 5000-B(config- vsan) #vsan 100 name FCoE-VLAN 100
  3. Nexus 5000-A#configure terminal 
    Nexus 5000-B (config) # vsan database 
    Nexus 5000-A (config)# vsan 100 
    Nexus 5000-A (config-vsan) # fcoe vsan 100
  4. Nexus 5000-B# configure terminal 
    Nexus 5000-B(config-vsan) # vlan 100 
    Nexus 5000-B (config-vsan)# vsan 100 name vsan100
Correct answer: A
Explanation:
Reference https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/fcoe/421_n1_1/b_Cisco_n5k_fcoe_config_gd_re_421_n1_1/Cisco_n5k_fcoe_config_gd_re_421_n1_1_chapter4.html
Reference https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/fcoe/421_n1_1/b_Cisco_n5k_fcoe_config_gd_re_421_n1_1/Cisco_n5k_fcoe_config_gd_re_421_n1_1_chapter4.html
Question 2
Which feature allows Cisco Nexus 7000 Series switches to be virtualized at the device level?
  1. PONG
  2. VLAN 
  3. VRF
  4. VDC
Correct answer: D
Explanation:
Reference https://www.cisco.com/c/en/us/products/collateral/switches/nexus-7000-10-slot-switch/White_Paper_Tech_Overview_Virtual_Device_Contexts.html
Reference https://www.cisco.com/c/en/us/products/collateral/switches/nexus-7000-10-slot-switch/White_Paper_Tech_Overview_Virtual_Device_Contexts.html
Question 3
A Cisco UCS chasis has two power suppliers connected to one PDU and two power supplies connected to another PDU. You would like to protect against the failure of one entire PDU. 
In this scenario, which power policy should you configure in UCS Manager?
  1. N+1
  2. redundant
  3. N+2
  4. grid
Correct answer: D
Explanation:
Reference https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/3-0/b_UCSM_GUI_User_Guide_3_0/b_UCSM_GUI_User_Guide_3_0_chapter_0100010.html
Reference https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/3-0/b_UCSM_GUI_User_Guide_3_0/b_UCSM_GUI_User_Guide_3_0_chapter_0100010.html
Question 4
Your customer needs a new Nexus switch that can support at least ten 40GbE ports, and has room for future growth. Your customer would also like the new switch to be Application Centric Infrastructure- ready. 
Which switch meets these requirements?
  1. Nexus 7004
  2. Nexus 5672
  3. Nexus 6004
  4. Nexus 9504 
Correct answer: D
Explanation:
Reference https://www.cisco.com/c/en/us/products/collateral/cloud-systems-management/application-policy-infrastructure-controller-apic/datasheet-c78-732414.html
Reference https://www.cisco.com/c/en/us/products/collateral/cloud-systems-management/application-policy-infrastructure-controller-apic/datasheet-c78-732414.html
Question 5
After deploying a FlexPod solution, which tool would you use to validate a successful installation?
  1. Hardware Universe
  2. Config Advisor
  3. System Manager
  4. UCS Manager
Correct answer: C
Explanation:
Reference https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_saphana_n9k_aff.html
Reference https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_saphana_n9k_aff.html
Question 6
You are attempting to establish a cluster peer relationship between two NetApp clusters, but the peering process fails. 
What is a cause for this failure?
  1. The intercluster LIF on each node cannot communicate with the intercluster LIF on each node in the peer cluster.
  2. The cluster LIFs on each node cannot communicate with the cluster LIFs on each node in the peer cluster.
  3. The node management LIF on each node cannot communicate with the node management LIF on each node in the peer cluster.
  4. The cluster management LIF for the cluster cannot communicate with the cluster management LIF for the peer cluster.
Correct answer: A
Explanation:
Question 7
The NetApp Vistual Storage Console is used to set which three setting categories on ESXi hosts? (Choose three.)
  1. MPIO Settings
  2. Adapter Settings
  3. Logging Settings
  4. NFS Settings
  5. Security Settings
Correct answer: ABD
Explanation:
Reference https://library.netapp.com/ecm/ecm_download_file/ECMLP2371569
Reference https://library.netapp.com/ecm/ecm_download_file/ECMLP2371569
Question 8
A server administrator calls you complaining that an uplink on both UCS Fabric Interconnects went down. Each Fabric Interconnect has a vPC to the Nexus 500 switches. After logging in to the switches, you notice that all vPC member ports on the secondary vPC peer switch are down. The vPC peer keepalive is still operational. 
What is the problem in this scenario?
  1. The vPC peer link is down.
  2. Both UCS Fabric Interconnects rebooted.
  3. The vPC feature is disabled.
  4. A new VLAN was added to the UCS vPC member ports.
Correct answer: A
Question 9
An administrator has a FlexPod solution with VMware vSphere. The administrator is migrating all network traffic from standard switches to vSphere distributed switches. Virtual machines (VMs) are currently using VM port groups called VLAN_500 and VLAN_501 on standard virtual switch vSwitch3. A new distributed switch called dvSwitch_VM is created and new distributed port groups are configured for each VM traffic VLAN. VMs are configured to use the new port groups. After the change, VMs on VLAN 501 report a loss of network connectivity; however, VMs on VLAN 500 are not showing any connectivity issues. The symptoms are experienced for VMs on all ESXi hosts. 
Which action must the administrator perform to solve the problem?
  1. Reboot the virtual machines to re-establish network connectivity.
  2. Create a new vmkernel port on dvSwitch_VM for VLAN 501.
  3. Configure the dvSwitch_VM port binding to Ephemeral.
  4. Add the correct VLAN ID to the new distributed port group for VLAN 501.
Correct answer: C
Question 10
Which two database types are supported with the VMWare vCenter 6.0 Server Appliance? (Choose two.) 
  1. Oracle
  2. vPostgres (embedded)
  3. Microsoft SQL Server Express
  4. Microsoft SQL Server Enterprise
Correct answer: AB
Explanation:
Reference https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_esxi60_n9k.html
Reference https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_esxi60_n9k.html
HOW TO OPEN VCE FILES

Use VCE Exam Simulator to open VCE files
Avanaset

HOW TO OPEN VCEX AND EXAM FILES

Use ProfExam Simulator to open VCEX and EXAM files
ProfExam Screen

ProfExam
ProfExam at a 20% markdown

You have the opportunity to purchase ProfExam at a 20% reduced price

Get Now!